FSS FLOW SAMPLING SYSTEM
Monitor and
Record Stormwater or Industrial Discharge Flow
|
 |
FEATURES:
 |
Ideal for wastewater, industrial, and environmental
flow sampling
|
 |
Simple to operate – no programming required
|
 |
Lightweight and easy to carry
|
 |
Rugged construction for harsh environments
|
 |
Over 20 pre-programmed flume and weir tables for
ease of use and flexibility
|
 |
Scalable flow proportional sample triggering
|
 |
Adjustable and repeatable sample volume
|
 |
Peristaltic pump prevents sample contamination
|
 |
Flow Data Recorder is Windows and Palm Pilot
compatible
|
 |
Open Channel Flow Monitor has an easy 4-button
programming system
|
 |
Upgradeable to include 6 additional water
quality parameters
|
 |
The easiest and most reliable method for collecting
water samples
|
|
On this page:
|
Downloads (PDF):
|
Additional Information:
|
|
Global Water's Flow Sampling System is a unique water
monitoring package. This package includes an
easy-to-use lightweight composite water sampler, an
open channel flow monitor with dual displays and
outputs, and a data recorder that is both Windows and
Palm Pilot compatible. This compact package is
portable for field installation and fully customizable
to meet your monitoring needs.
Water Sampler
Global Water's flow-proportional water sampler is
enclosed in a rugged, rainproof, lockable carrying
container. The water sampler includes a 2-gallon
polyethylene wastewater sample bottle for collecting
composite samples, a peristaltic sampling pump, a
two-knob control panel (no programming required), and
a rechargeable gel cell battery. Also provided is a
sample pickup hose and a battery charger. Optional
additions include glass sample bottles, refrigerated
containers, portable ice containers and more. Visit
the WS300 Wastewater Sampler page for more
information on the flow proportional composite water
sampler.
Open Channel Flow
Monitor
Global Water's FC200 Open Channel Flow Monitor is
reliable and accurate for measuring and totalizing
open channel flows for all flumes and weirs, as well
as any gravity-type open-channel flows. The flow
monitor is pre-programmed with over 20 different flume
and weir characteristics and can also be programmed
for your unique application. The unit measures water
depth with Global Water's highly accurate
pressure
transducer and instantly calculates (for display
and output) water flow and totalizer values for any
depth-to-flow relationship in any engineering units.
The Open Channel Flow Monitor is easily set up in the
field using a unique four-button programming system.
Visit the
FC200 Open Channel Flow Monitor page for more
information.
Flow Data Recorder
Global Water's flow data recorder includes
Windows-based and Palm Pilot software, which provide
many useful features, such as real time monitoring,
measurement interval and engineering unit selections,
station ID, and sensor calibration. The Global Water
Software makes accessing stored data and setting
options easy. The data recorder monitors and logs
both flow rate and total flow for your records. Data
downloaded from the recorder can easily be opened in
any PC spreadsheet program for analysis and graphic
presentation. Visit the
GL400-1-1 Datalogger page for more information.
|
WS300 Wastewater Sampler:
Composite Sample
Size:
25
mi to 600 ml as set by user (two gallon composite
sample maximum)
Size:
9"L
X 17"W X 22"H
Weight:
22lb
(Shipping Weight 24lb)
Operating
Temperature:
0-70°C
Materials:
Enclosure:
Expanded UV protected by PVC
Bottle:
Two
gallon polyethylene
Sample Tubing:
Polyethylene
Logic
Timer/Controller:
CMOS
Solid State (fully potted in epoxy)
Sample Hose:
One
15' nylon reinforced 1/4" ID polyethylene flexible
tubing sections with intake strainer. Hose may be
extended, as required, using standard 1/4" tubing and
fittings.
Sample Pump:
Flow Rate:
1000 ml per
minute at 4 ft. head
Type:
Peristaltic
Maximum Lift:
22'
Battery:
Rechargeable 5 AH Gel Cell. The battery will power
the sampler for a minimum of four months including
five 24-hr. storm events before recharging is
required.
FC200 Open Channel Flow Monitor:
Rate Display:
6 digit +
decimal place, LCD
Totalizer Display:
6 digit + decimal
place, LCD
Accuracy:
Pressure transducer: +0.2% FS, Flow Monitor:
+0.01% + the depth-flow-table error
Flow Units: CFS,
GPM, m3s, MGD
Totalizer:
Related to Flow Units
Enclosure: 4
3/4" W x 8" H x 3" D, NEMA 4X (IP67)
Power: 120 VAC
to 240 VAC, optional: Battery powered (Must be
specified at time of ordering)
Pre-defined Tables:
Parshall:
1", 2", 3", 6", 9", 12"
Palmer-Bowlus (4D):
4", 6", 8", 10", 12", 15"
Weir: 45° V
notch, 90° V notch, 1' rectangular, 2' rectangular
H: 0.4HS,
0.6HS, 0.5H, 0.75H, 1.0H, 1.5H, 2.0H
Trapezoidal: 60°
Custom Table:
Equation or look up table provided at time of order.
Allow for longer lead times for custom table entry.
GL400-1-1 Datalogger:
Memory:
Non-volatile flash
memory
Resolution:
12-Bit
Channels:
1-Analog, 1-Pulse
Storage Capacity:
19,500 time and date
stamped data points per channel
Recording Rate:
Linear fixed intervals from 1 per second to every
32,000 seconds (also 0-32,000 minutes, hours and
days); Logarithmic test (for pump and slug testing)
Data Overwrite:
Select memory wrap or unwrap (unwrap will stop logging
data once memory is full)
Clock:
Synchronizes to the time and date of user's computer
Operating Temperature:
-40° to +170°F
Enclosure:
ABS plastic (5" x 3" x 3")
Optional Weather-Proof Enclosure Expanded UV protected
PVC (9" x 7.5" x 4.5")
Optional Battery:
12 Volt, 2.2 A/hr.,
Rechargeable (Gell Cell) (Included with Weather-Proof
Enclosure)
Weight: 3.5 lbs
|
FSS Flow Sampling
System
Includes flow-proportional composite water
sampler, open channel flow monitor, and flow data
recorder.
|
$2,965
|
|
FSS Data Recorder
Upgrade
Upgrade your data recorder to add 6 additional
analog channels in order to record water quality
parameters such as pH, DO, and conductivity.
Visit our water quality page for more
information about Global Water's water quality
sensors.
|
additional
$200
|
|
Deluxe Palm
Package
Handheld Palm Pilot download package for the flow
data recorder.
|