U-10 MULTIPARAMETER WATER QUALITY METER
Meter for
Monitoring pH, Conductivity, Dissolved Oxygen,
Turbidity, Salinity, and Temperature
(NEW
PRODUCT!)
|
 |
FEATURES:
 |
Rugged
|
 |
Fully submersible sensor
|
 |
Ideal for multi-parameter water quality measurements
without having a permanent installation
|

|
On this page:
|
Additional Information:
|
|
Global Water's U-10 Multiparameter water quality meter
brings laboratory accuracy and the ease of push-button
operation to water quality measurement in the field.
Six parameters can be measured : pH, temperature,
dissolved oxygen, electrolytic conductivity,
turbidity, and, salinity. Featuring a powerful sensor
and state-of-the-artfunctions, the Multiparameter
water quality meter makes it easy to get highly
reliable water quality data simply and quickly just by
submersing the sensor in the water. The
Multiparameter water quality meter is flexible enough
to use for cheeking the quality of a broad range of
water samples, from factory effluent to urban
drainage, river water, lake and marsh water, aquatic
culture tanks, agricultural water supplies, and sea
water. The main unit is water resistant, so it can be
used safely even in the rain.
Automatic Calibration
The U-10 Multiparameter water quality meter has an
automatic calibration function that calibrates the
instrument simply at the touch of a button for more
highly reliable data. What used to be a complicated
calibration process is now easy. Just fill the
supplied beaker with the standard solution, immerse
the sensor and press a button once for one-point
calibration for each of the four parameters pH,
conductivity, turbidity and DO. Two-point calibration
is also possible should more precise data be required.
Automatic Salinity
Correction
The U-10 Multiparameter water quality meter has an
automatic salinity function that makes it possible to
measure DO in both fresh water and salt water. It is
now possible to measure DO in either fresh or salf
water with the same instrument. When measuring DO in
salt water, it will automatically measure the salt
concentration and make the salinity correction. It is
also possible to set a freely selectable salinity
correction factor of between 0 and 4 percent.
Limited Data Logger
20 samples of data for all 6 parameters can be stored
in memory to be recalled later for display and print
out. Store the results of measurement of all six
parameters for up to 20 samples. There is no need to
record measured values on site. Data stored in memory
can be recalled and displayed at any time, and can
even be simultaneously printed out on any standed
printer by connecting it to the Centronics-specification
printer output terminals.
The standard handheld multi-parameter water quality
measurement system comes with:
 |
Carrying case with strap for handheld
multi-parameter meter and water-quality probe
|
 |
Handheld Multiparameter water quality meter with
water quality probe
|
 |
Instruction manual
|
 |
pH
4 Buffer
|
 |
Reference inner solution
|
 |
Calibration beaker
|
 |
DO
installation tool
|
|
PARAMETERS
|
pH
|
CONDUCTIVITY
|
TURBIDITY
|
DISSOLVED OXYGEN
|
TEMPERATURE
|
SALINITY
|
PRINCIPLE
|
Glass electrode
|
Alternating four-electrode
|
Scattering/transmitting light
|
Membrane/galvanic cell
|
Thermistor
|
(Alternating four-electrode)*
|
RANGE
|
0-14 pH
|
0-100 mS/cm
|
0-800 NTU
|
0-19.9 mg/l
|
0-50° C
|
0-4 %
|
RESOLUTION
|
STANDARD
|
0.1 pH
|
(mS/cm) (mS/cm)
0-1 :0.01
1-10 :0.1
10-100 :1
|
10 NTU
|
0.1 mg/l
|
1° C
|
0.1%
|
EXPANDED
|
0.01 pH
|
(mS/cm) (mS/cm)
0-1 :0.001
1-10 :0.01
10-100 :0.1
|
1 NTU
|
0.01 mg/l
|
0.1° C
|
0.01%
|
REPEATABILITY
|
+0.05 pH
|
+1% of full scale
|
+3% of full scale
|
+0.1 mg/l
|
+0.3° C
|
+0.1 %
|
TEMP. COMPENSATION
|
0-50° C
|
0-50° C
|
N/A
|
0-40° C
|
N/A
|
N/A
|
CALIBRATION
|
Auto one-point calibration,
manual two-point calibration.
|
Auto one-point calibration,
manual two-point calibration.
|
Auto one-point calibration,
manual two-point calibration.
|
Auto one-point calibration
(air), manual two-point calibration.
|
N/A
|
N/A
|
DISPLAY
|
LCD
|
PRINTER OUTPUT
|
Centronics
|
POWER
|
Battery 6F22(S-006P)x1pc.
|
SENSOR ASSEMBLY
|
Standard: sensor with 2 m
cable. Optional: Sensor with 10 m cable.
|
WEIGHT
|
Main Unit: ~400g(0.9lbs),
Sensor Assembly (2 m cable): ~800g(1.8lbs)
|
|
Note:
* Salinity is calculated from the conductivity
data |
U-10
Multiparameter Probe
Probe includes 2 m cable.
|
$2,850
|
U-10
Multiparameter Probe (with 10 m cable)
Longer cable lengths available on request.
Specify cable length when ordering.
|
$3,200
|
|
U-10 Flow Cell |
$480 |
|
U-10 REPLACEMENT
PARTS |
|
|
pH sensor |
$86 |
|
DO sensor |
$369 |
|
Reference sensor |
$80 |
RELATED PRODUCTS
|
U-22XD Multiparameter Probe
Use the multiparameter probe to monitor 10
different parameters, including total suspended
solids,
water depth, and ORP. |
$5320 |
W-21 SDI-12 Multiparameter Probe
Analyze eight water quality parameters with
SDI-12 output. |
$4070 |
Water quality sensors for permanent
installation.
|
|
|
|