Environmental Catalogue

BACK TO CATALOGUE

WL400 Water Level Sensor

 

WL400 WATER LEVEL SENSOR
Submersible Pressure Transducer for Level & Pressure

water level sensor,submersible pressure transducer

FEATURES:

bullet

High accuracy and reliability

bullet

Completely submersible pressure transducer and cable

bullet

Compact, rugged design for easy installation

bullet

Minimal maintenance and care

bullet

Water level sensor compatible with most monitoring equipment

bullet

4-20mA output

bullet

Vented cable for automatic barometric compensation

bullet

Multiple level ranges available from 3' to 250'

bullet

Wet-wet water level sensor eliminates vent tube concerns

bullet

Dynamic temperature compensation system

bullet

Submersible pressure transducer not affected by foam, wind, or rain

bullet

Monitors levels in groundwater wells, rivers, streams, tanks, lift stations and open channels

On this page:

- Product Description
- Specifications
- Installation
- Applications
- Options & Prices

Downloads (PDF):

- Water Level Sensor Quick Reference Sheet
- Water Level Sensor Manual*

*May take several minutes to download, depending on your internet connection speed.

Additional Information:

- Product Support
- Water Level Monitoring and Why You Need Barometric Compensation
- WL15 Water Level Logger

Product Description

Global Water's WL400 Water Level Sensor provides highly accurate water level measurement for a wide variety of applications, including those in severe environments.  The submersible pressure transducers have a dynamic temperature compensation system, enabling high accuracy measurements over a wide temperature range.  The water level sensor is easily adapted to all dataloggers, telemetry, monitoring equipment, and displays.

Each of the water level sensors consist of a solid state submersible pressure transducer encapsulated in a stainless steel 3/4" diameter housing.  The water level sensor has a molded-on waterproof cable and a two-wire 4-20 mA high level output for connection to a monitoring device.  A 25' cable is standard, and optional cable lengths are available up to 500'.

The Water Level Sensor's submersible pressure transducer is fully encapsulated with marine-grade epoxy so that moisture can never leak in or work its way down the vent tube to cause drift or level sensor failure (as is the case with other pressure sensors).  The water level sensor uses a unique, highly flexible silicon diaphragm to interface between water and the sensing element.  This silicon diaphragm protects the water level sensor's electronics from moisture and provides each sensor with exceptional linearity and very low hysteresis.  The design of the submersible pressure transducers eliminates the issues associated with metal foil diaphragms, which tend to crinkle and stretch out over time causing drift, linearity, and hysteresis problems.  The water level sensor is also has automatically barometric compensation due to the attached vent cable and protected by a stainless steel micro-screen cap, which makes fouling with silt, mud, or sludge virtually impossible.

Pressure transducer level ranges of 0-3', 0-15', 0-30', 0-60', 0-120' and 0-250' are available.  The 0-3' low-level range is ideal for measuring shallow flows or small water level changes like those encountered in sewers, storm drains, weirs, and flumes.  The 0-3' water monitoring sensor accurately measures small changes in water, even when the water's depth is only a few inches deep.  Other metal foil-type water level sensors typically have serious problems at low-level ranges because of sensor crinkling, stretching, and drifting.

Each submersible pressure transducer has a two-wire 4-20 mA output signal that is linear with water depth.  From 10 to 36 VDC is required to operate the water level sensor, so the level sensors can be operated from common 12 VDC battery systems.  The 4-20 mA signal can run up to 3,000' from the submersible pressure transducer to the logging device.  Common twisted pair or electrical extension cord wire may be spliced to the vented cable once the cable is out of the water.  The 4-20 mA signal may be converted to 0.5 to 2.5 VDC by dropping the current signal across a 125 ohm resistor.

Specifications

Sensing Element

Sensor Element: Silicone Diaphragm, Wet/Wet Transducer
Pressure Range: 0-3', 0-15', 0-30', 0-60', 0-120',0-250'
Linearity and Hysteresis:
±0.1% FS
Accuracy:
±0.1% of full scale at constant temperature, ±0.2% over 35°F to 70°F range
Overpressure: Not to exceed 2 x full scale range
Resolution: Infinitesimal (Analog)
Outputs: 4-20 mA or 0.5 to 2.5 VDC across 125 ohms
Supply Voltage: 10 to 36 VDC
Current Draw: Same as sensor output
Warm Up Time: 10 ms minimum
Operating Temperature: -40° to +185°F
Compensation: Uses dynamic temperature compensation 30-70 F.  Automatic barometric pressure compensation
Weight: 1/2 lb

 

Housing

Material: 304L Stainless Steel, SS microscreen (hundreds of holes to prevent fouling), electronics are fully encapsulated in marine grade epoxy, guaranteed not to leak
Size: up to 5 1/2" long x 13/16" diameter (small enough for a 1" well)

 

Cable

Conductors: 4 each 22 AWG
Jacket Material: Marine Grade Polyurethane
Vent Tube Material: HD Polyethylene
Shield: Aluminum Mylar
Outer Diameter: "307"
Temperature Range: -22° to +185°F
Weight: 0.7 oz/ft Length:  Standard 25' (up to 500' from the factory)

Installation

The submersible pressure sensor may be placed slightly below the lowest expected water level.  Water level sensor level ranges of 0-3', 0-15', 0-30', 0-60', 0-120' and 0-250' are available.  When ordering, select the level sensor range that will cover the maximum water level change (this is not necessarily the total depth of water).  Selecting the smallest water level range possible will ensure the greatest accuracy.

The 4-20 mA signal can run up to 3,000' from the water level sensor to the logging device.  Common twisted pair or electrical extension cord wire may be spliced to the vented cable once the cable is out of the water.  The 4-20 mA signal may be converted to 0.5 to 2.5 VDC by dropping the current signal across a 125 ohm resistor.

Applications

The WL400 Water Level Sensor can be used to measure water level, well depth, groundwater level, surface water flow, pipe flow, and water pressure, etc...

Options & Prices

WL400 Water Level Sensor
When ordering, specify water level range that will cover the maximum water level change for your application (this is not necessarily the total depth of water): 0-3', 0-15', 0-30', 0-60', 0-120', 0-250'. Selecting the smallest water level range possible will ensure the greatest accuracy. Includes 25 feet of cable.

$495

 

WLEXC  Extra Cable
Cable length is measured from top of logger to bottom of sensor. WL400 includes 25 feet of cable, and extra cable can be added up to 500 feet.

$1.30/ft

 

WL400-WW Waste Water Sensor
Viton membrane for harsh water environments.  Accuracy 0.5% of full scale.

additional $75

Submersible pressure transducer wastewater option

WL400-PRP Pressure Pipe Option
Water level sensor is housed in a 6" PVC or stainless steel pipe with 3/4" NPT male thread for logging pressure in municipal water systems.  10' cable standard.  Calibrated in psi with ranges of 0 to 30 psi, 60 psi, 100 psi available.

$35 PVC or $65 Stainless Steel

 

WL400-SWO Sewer Flow Option
Mouse-shaped cover protects sensor from fouling and velocity effects in sewer, stormwater and irrigation pipe flows.  Mouse is attached to 4" X 24" stainless steel strap for mounting sensor on pipe bottom.

additional $60

water level sensor sewer flow protection

EZ100 EZ Sensor Display
LCD readout display for both portable use and permanent installations.

$315

Water level sensor,submersible pressure transducer display

WL15X Water Level Logger
Submersible pressure transducer and datalogger for recording water level data.

$795

 

 